Swelltite® Cast-In-Place Concrete Details

Below are standard details provided in both AutoCAD .dwg and Acrobat .pdf file formats. For your convenience the details are grouped by the following applications:

Don’t see what you’re looking for? Click here to request a Job Specific Detail

  • 200 Series - BACKFILLED WALLS
  • 400 Series - PLAZA DECKS

For shotcrete, precast concrete, and project specific details, contact CETCO Technical Support for assistance at 1.800.527.9948.

200 SERIES - BACKFILLED CONCRETE WALLS

Detail Description File Format
DWG PDF
ST-200 C-I-P Concrete Wall Fastener Installation Detail Link Detail Link
ST-201 C-I-P Concrete Wall Adhesive Installation Detail Link Detail Link
ST-202 Masonry Block Wall Fastener Installation Detail Link Detail Link
ST-203 Masonry Block Wall Adhesive Installation Detail Link Detail Link
ST-204 Concrete Wall/Footing Joint (Non-Hydrostatic) Detail Link Detail Link
ST-205 Concrete Wall/Footing Joint (Hydrostatic) Detail Link Detail Link
ST-206 Masonry Wall/Footing Joint (Non-Hydrostatic) Detail Link Detail Link
ST-207 Concrete Wall with Flush Footing (Non-Hydro) Detail Link Detail Link
ST-208 Typical Pipe Penetration Detail Link Detail Link
ST-209 Multiple Pipe Penetrations Detail Link Detail Link
ST-210 Multiple Pipe Penetrations (Wide Gap) Detail Link Detail Link
ST-211 Sleeved Pipe Penetration Detail Link Detail Link
ST-212 Inside Wall Corner Detail Detail Link Detail Link
ST-213 Concrete Form-Tie Detailing Detail Link Detail Link
ST-214 Typical Grade Termination Detail Link Detail Link
ST-215 Grade Termination with UV Membrane Detail Link Detail Link
ST-216 Thru-Wall Flashing Grade Termination Detail Link Detail Link
ST-217 Grade Termination with Architectural Finish Detail Link Detail Link
ST-218 Expansion Joint Cover Detail Link Detail Link
ST-219 Insulation Board over Aquadrain and Swelltite Detail Link Detail Link
ST-220 Seamtape at Overlat Concrete Wall Detail Detail Link Detail Link
ST-221 Seamtape at Overlap Masonry Wall Detail Detail Link Detail Link


400 SERIES - PLAZA DECK DETAILS

Detail Description File Format
DWG PDF
ST-400 Deck with Concrete Topping Slab Detail Link Detail Link
ST-401 Deck with Insulated Concrete Topping Slab Detail Link Detail Link
ST-402 Deck with Concrete Pavers on Sand Layer Detail Link Detail Link
ST-403 Deck with Concrete Pavers on Grout Layer Detail Link Detail Link
ST-404 Split-Slab Deck Section Detail Detail Link Detail Link
ST-405 Typical Concrete Paver Deck Section Detail Detail Link Detail Link
ST-406 Typical Deck Drain Detail Detail Link Detail Link
ST-407 Typical Deck Pipe Penetration Detail Link Detail Link
ST-408 Seamtape Membrane Overlap Detail Detail Link Detail Link
ST-409 Deck to Wall Transition Corner Detail Link Detail Link
ST-410 Deck to Slab Edge Detail Detail Link Detail Link